Cold Voc, hot Vmp, MPPT voltage and current checks / Dimensionamiento preliminar de cadenas solares con temperatura.

US$9 one-time · Manual license request, no online checkout.

Request license / Solicitar licencia

Why temperature matters / Por qué importa la temperatura

At low cell temperature, PV module open-circuit voltage (Voc) typically rises and can exceed an inverter's absolute DC input limit. At high cell temperature, maximum-power voltage (Vmp) typically falls and may drop below the MPPT tracking window. Parallel strings also increase operating and short-circuit current.

En frío, Voc normalmente aumenta; en calor, Vmp disminuye. Las cadenas en paralelo suman corriente. Por eso el número de paneles en serie debe revisarse con los límites reales del inversor y la ficha del módulo.

Cold Voc
Compare temperature-adjusted string Voc against absolute DC maximum.
Hot and cold Vmp
Compare both operating extremes against the MPPT tracking window.
Parallel strings
Check Imp and Isc against per-MPPT input limits.
Offline handover
Print PDF, export CSV, save/restore project JSON.

Free worked example / Ejemplo gratuito

Illustrative inputs only, not a real inverter or module recommendation. Replace with exact manufacturer data.

Input / DatoExample / Ejemplo
PV module Pmax / Potencia550 W
Module Voc / Vmp (STC)49.9 V / 41.9 V
Voc / Vmp temperature coefficients−0.275%/°C / −0.350%/°C
Cell temperature min / max0°C / 70°C
MPPT range; absolute DC max120–450 V; 500 V
Series × strings/MPPT × MPPTs8 × 2 × 1 = 16 modules
Calculated cold string Voc426.65 V (< 500 V)
Calculated hot string Vmp282.41 V (> 120 V)
Calculated operating current / MPPT26.26 A (Imp 13.13 A × 2)
Array nameplate DC power8.80 kWp

Formula: V(T) = V(STC) × [1 + coefficient (%/°C)/100 × (cell temperature − 25°C)]. Example cold Voc = 8 × 49.9 × [1 + (−0.275/100) × (0 − 25)] = 426.65 V.

What the licensed worksheet includes / Qué incluye

Editable project, customer and equipment information; temperature-corrected voltage results; indicative series range; seven validation checks; comparison against module inventory and inverter current limits; browser autosave; JSON backup/restore; CSV export; and a print-ready bilingual report.

Herramienta local para instaladores solares, proyectos de bombeo, técnicos y presupuestistas. Sin mensualidades, servidor ni conexión a Internet.

Important engineering limitations / Limitaciones

The software is a preliminary calculation worksheet, not electrical design approval or safety certification. Cell temperature differs from ambient temperature. Check manufacturer startup requirements, exact MPPT ratings, allowable strings per MPPT, wire sizing, fuses, overcurrent protection, grounding, surge protection, installation rules and local codes. The worked example is not a procurement recommendation.